Spot human monocyte chemoattractant protein-1 ELISA detection kit

This reagent is for research use only: Serum or plasma test principle: MCP-1 kit is a solid-phase sandwich enzyme-linked immunosorbent assay (ELISA). Standards with known MCP-1 concentration and samples with unknown concentration are added to microwells The detection is carried out in the microplate. First, MCP-1 and biotin-labeled antibody were incubated simultaneously. After washing, HRP labeled with avidin was added. After incubation and washing, the unbound enzyme conjugate is removed, and then substrates A and B are added to act simultaneously with the enzyme conjugate. Produce colors. The color depth is proportional to the concentration of MCP-1 in the sample. Bring your own material distilled water. Sampler: 5ul, 10ul, 50ul, 100ul, 200, 500ul, 1000ul. Oscillator and magnetic stirrer etc. Safety Avoid direct contact with the stop solution and substrates A and B. Once exposed to these liquids, rinse with water as soon as possible. Do not eat, drink, smoke or use cosmetics during the experiment. Do not use your mouth to absorb any ingredients in the kit. Handling precautions Reagents should be stored according to label instructions, and returned to room temperature before use. The sparse standards should be discarded and cannot be stored. The slats not used in the experiment should be immediately returned to the packaging bag, sealed and stored to avoid deterioration. Unused other reagents should be packed or covered. Do not mix reagents of different batches. Use before warranty. Use a disposable pipette tip to avoid cross-contamination, and avoid using a sampler with a metal part when drawing the stop solution and substrates A and B. Use a clean plastic container to prepare the washing solution. Mix all components and samples in the kit thoroughly before use. When washing the enzyme-labeled plate, it should be fully patted dry. Substrate A should evaporate to avoid opening the lid for a long time. Substrate B is sensitive to light and avoid prolonged exposure to light. Avoid contact with hands, it is toxic. The OD value should be read immediately after the experiment is completed. The order of adding reagents should be the same to ensure that all wells are incubated for the same time. Perform the incubation operation according to the time, the amount and order of the liquid indicated in the instructions. Sample collection, processing and storage methods Serum-avoid any cell stimulation during the operation. Use test tubes free of pyrogens and endotoxins. After collecting blood, centrifuge at 1000 × g for 10 minutes to separate the serum and red blood cells quickly and carefully. Plasma ----- EDTA, citrate, heparin plasma can be used for detection. Centrifuge at 1000 × g for 30 minutes to remove particles. The cell supernatant was centrifuged at 1000 × g for 10 minutes to remove particles and polymers. Storage ------ If the sample is not used immediately, it should be divided into small parts and stored at -70 ℃ to avoid repeated freezing. If possible, do not use hemolysis or hyperlipidemia. If there are a large number of particles in the serum, centrifuge or filter before testing. Do not thaw at 37 ° C or higher. Thaw at room temperature and ensure that the sample is thawed evenly and adequately. Reagent preparation standards: Serial dilutions of standards should be prepared during the experiment and cannot be stored. Before dilution, the standard was shaken and mixed with the dilution of the washing buffer (50 ×): distilled water was diluted 50 times. Before use, mix all reagents thoroughly. Don't make the liquid generate a lot of foam, so as to avoid adding a large number of bubbles during sample addition, which will cause errors in sample addition. The number of slats required is determined by the number of samples to be tested plus the number of standard products. It is recommended to make multiple holes for each standard and blank hole. Each sample is determined according to its own quantity, and those that can use multiple holes can be used as much as possible. Add 50ul of the diluted standard to the reaction well and 50ul of the sample to be tested in the reaction well. Immediately add 50ul of biotin-labeled antibody. Cover the membrane plate, gently shake and mix, and incubate at 37 ° C for 1 hour. Shake off the liquid in the wells, fill each well with washing liquid, shake for 30 seconds, shake off the washing liquid, pat dry with absorbent paper. Repeat this operation 3 times. If washing with a plate washer, the number of washes is increased once. Add 80 ul of streptavidin-HRP to each well, gently shake and mix, and incubate at 37 ° C for 30 minutes. Shake off the liquid in the wells, fill each well with washing liquid, shake for 30 seconds, shake off the washing liquid, pat dry with absorbent paper. Repeat this operation 3 times. If washing with a plate washer, the number of washes is increased once. Add 50ul of substrate A and B to each well, mix gently by shaking, and incubate at 37 ° C for 10 minutes. Avoid light. Remove the enzyme labeling plate and quickly add 50ul of stop solution. After adding the stop solution, the results should be measured immediately. The OD value of each well was measured at a wavelength of 450 nm. The results above the No. 6 standard are non-linear, and accurate results cannot be obtained based on this standard curve. Kit performance 1. Sensitivity: The minimum detection concentration is less than No. 1 standard. Linearity of dilution. The correlation coefficient between the linear regression of the sample and the expected concentration is 0.990. 2. Specificity: Does not react with other cytokines. 3. Repeatability: The coefficients of variation within and between plates are less than 10%. Judgment and analysis of results 1. Instrument value: read the OD value of each well on a microplate reader with a wavelength of 450 nm. 2. Take the absorbance OD value as the ordinate (Y), and the corresponding MCP-1 standard concentration as the abscissa (X ), The corresponding curve is made, and the MCP-1 content of the sample can be converted from the standard curve to the corresponding concentration according to its OD value. 3. Detection value range: 0-800pg / ml 4. Sensitivity: 1.0 pg / ml CLS1077-1-200ml cell separation solution 1.077 (FICOLL configuration) 200ml CLS1083-200ml cell separation solution 1.083 200ml CLS1092-200ml cell separation solution 1.092 200ml CLS1113-200ml cell separation Solution 1.113 200ml CLS1119-200ml Cell Isolation Solution 1.119 200ml RC085-20ug Recombinant Murine GM-CSF Recombinant Mouse Granulocyte-Macrophage Colony Stimulating Factor 20ug DAH1034-1ml Anthrax Paper antigen Healthy Skin Sheet Anthrax Antigen 1ml DAH1028-100ml FBS Premium Fetal Bovine Serum 100ml DAH1029-200ml FBS Excellent Grade fetal bovine serum 200mlDAH1030-200ml FBS Standard fetal bovine serum 200mlDAH1031-200ml Newborn calf serum Newborn calf serum 200ml

It is essential for cat owners to have cat litter box at their home, as cats are self-maintained pets that go to toilets by themselves. We supply many different sizes and shapes of cat litter box in our range that you can fulfill the needs of different cat owners. Cat litter scoops are also included in the range to go with the cat litter box.

Cat litter box

Cat litter scoop

 

Cats naturally groom themselves, however, we also provide cat slicker brush with round pointed tips for cat owners to groom and massage their cats at the same time.

Cat slicker brush




ABOUT US


PERCELL PET is established in 1978 with offices located in Taipei, Taiwan and Guangdong, China. Currently, Percell Pet partners with more than 49 distributors around the world and carries thousands of quality pet supplies for dogs, cats, birds, fresh and salt water fishes, reptiles and small animals, like rabbits and ferrets, etc from Taiwan and China.


We supply popular and classic pet products around the world and also OEM products at your needs.


  • FLEXIBLE IN ORDER VOLUME, orders can be done in LCL or full container, MOQ can be discussed accordingly.
  • COMMUNICATION, staffs are fluent in written English with in time replies.
  • SERVICE, provide help and solutions to your sourcing in Taiwan and China.



Cat Grooming & Hygiene

Cat Grooming Tool,Cats Hygiene Spray,Cat Grooming Comb,Cat Grooming Scissor

PERCELL PET SYSTEM CO., LTD , https://www.percell-pet.com

Posted on