How to measure the specific gravity of chlorinated paraffin


Chlorinated paraffin is a chlorinated derivative of paraffin hydrocarbon, which has the advantages of low volatility, flame retardancy, good electrical insulation, and low price. It can be used as a flame retardant and an auxiliary plasticizer for polyvinyl chloride. Widely used in the production of cables, floor materials, hoses, artificial leather, rubber and other products. As well as additives used in paints and lubricants.

The state of chlorinated paraffin is different due to its different chemical composition. Chlorinated paraffin 42 is light yellow viscous liquid, chlorinated paraffin 52 is light yellow to yellow oily viscous liquid, chlorinated paraffin 70 is dendritic powder, white or light yellow, etc. There are both solids and liquids, how to measure the specific gravity of chlorinated paraffin? Next, how to measure the specific gravity of chlorinated paraffin

(1) If the measured chlorinated paraffin is only liquid, our company Beijing Yitenuo recommends the use of liquid electronic hydrometer. The liquid electronic hydrometer is now introduced in detail

Principle of Liquid Electronic Hydrometer

Using Archimedes principle combined with modern electronic technology, direct digital display density, high measurement accuracy, stable and durable. Compared with the traditional Webster balance method and pycnometer method, the operation of this machine is simpler, and it is not affected by external factors and temperature, which can realize fast and accurate measurement.

The main purpose of liquid electronic hydrometer

Mainly aimed at: chemical solutions, modern energy, petroleum fuels, fine chemicals, chemical reagents, chemical research laboratories. It is suitable for density measurement in the fields of quality management, formulation modulation, cost control, and density research. Adopting Archimedes' principle, it conforms to GB / T 611, GB / T11540, GB / T12206, GB / T5518, and other standard specifications.

Specifications

1. Density analysis: 0.001 g / cm3

2. Measuring range: 0.001-7.800g / cm3

3. Measurement types: a: flowing liquid, viscous liquid, volatile liquid, corrosive liquid, high temperature liquid, suspended liquid, emulsified liquid, etc .; b: alcohol, flux, essence, blood, sodium chloride , Electrolyte, diesel, refrigerant, hydrofluoric acid, methylene chloride, sulfuric acid, etc. can be measured in similar state liquids.

Main functions and features:

1. The operation is in one step, which is convenient for multiple consecutive rapid tests.

2. Any solution can be quickly measured.

3. Digital display, high measurement accuracy, easy operation, stable and durable.

4. It can measure the density value of samples under normal temperature to 100 ℃.

5. Sampling is convenient, the measured sample only needs 50CC.

6. There is no cumbersome debugging and operation of Webster balance method and pycnometer method.

7. It can work with constant temperature water tank to measure the specific gravity of the liquid at the required temperature.

8. The measuring cup Rongjing is cleaned, not restricted by the small diameter of the pycnometer, and can be reused. Disposable measuring cups can also be used.

9. Volatile liquids, corrosive liquids, viscous liquids, strong acids and alkaline liquids can be quickly measured (relevant accessories are purchased).

10. With RS-232C communication interface, it is convenient to connect PC and printer, and DE-40 printer can be purchased to print measurement data.

11. It is equipped with special windproof and dustproof cover, which is convenient and durable.

Measurement steps of liquid electronic hydrometer:

â‘ Place the measuring cup with the sample on the measurement placement board, and deduct the weight of the hook.

â‘¡ Use the hook to hang the standard weight and completely immerse it in the liquid to be measured, and display the density value.

Standard accessories for liquid electronic hydrometer:

①Host, ②Measurement and placement board, ③DE-20A standard liquid measurement assembly, ④Tweezers, ⑤Thermometer, ⑥100G weight, ⑦Windproof and dustproof cover, ⑧Measurement bracket, ⑨A power transformer

※ DE-20A standard liquid measurement components: including 2 stainless steel hooks, 1 standard glass weight, 1 standard stainless steel weight, 2 measuring cups


(2) If the measured chlorinated paraffin is only solid, our company Beijing Yitenuo recommends the use of solid electronic hydrometer. The solid electronic hydrometer is now introduced in detail

The principle of solid electronic hydrometer DH-300

This machine adopts Archimedes principle, simple and convenient operation, fast measurement, accurate results, durable, economical and so on. Products comply with ASTM D792, GB / T 1033, HG4-1468, JIS-K-6268, ISO 2781, UL, IEC, CCC, VDE and other national standards.

The solid electronic hydrometer is the most widely used digital density measuring instrument with a precision of one-thousandth. It uses water as a medium and displays density values ​​in only two steps. Compared with the traditional solid electronic hydrometer, the machine does not need manual calculation, and the operation is convenient, time-saving, accurate and efficient.

Main uses: Widely used in the proportion of related solid products such as sheet, film, float, powder in rubber, plastic, wire and cable industries

Specifications

Density analysis: 0.001 g / cm3; maximum weighing: 300g; minimum weighing: 0.005 g / 0.01 g

Features of solid electronic hydrometer:

1. Directly read the density value, volume and percentage of any solid substance

2. Lijing, metal, PVC particles, EVA foam, powder, film, etc. can be quickly measured

3. Simple operation, convenient and fast measurement

4. Fully automatic zero tracking function

5. Use water as medium, but also other liquid medium

6. With actual water temperature compensation function

7. With buzzer function

8. Adopt integrally formed large-capacity design measuring accessories

9. Configure special wind and dust cover

Standard accessories:

① Host, ② sink, ③ measuring table, ④ tweezers, ⑤ thermometer, ⑥ 100G weight, ⑦ windproof and dustproof cover, ⑧ a set of accessories for measuring particles, ⑨ a set of accessories for measuring floating bodies, ⑩ a power transformer

Measurement steps:

â‘  First measure the weight of the product in the air, press ENTER to store the memory.

â‘¡ Put it in water again to measure the weight in water, press ENTER to store, and display the density value.



(3) If the measured chlorinated paraffin is both liquid and solid, it is recommended to use a solid-liquid dual-use electronic hydrometer. Now, the solid-liquid dual-use electronic hydrometer will be introduced in detail

The solid-liquid dual-use electronic hydrometer is currently the most widely used solid-liquid dual-use density meter. The solid is equipped with professional measuring accessories. The highly transparent integrated injection molded sink is wear-resistant, drop-resistant and corrosion-resistant. The liquid is equipped with a stainless steel measuring frame and standard measuring weights, and the design is more user-friendly. It has the characteristics of accurate measurement, simple operation, stability and durability. Equipped with special windproof and dustproof cover, the combination is convenient, strong and durable; with RS-232C communication interface, it is convenient to connect the PC and the printer, and the DE-40 printer can be purchased to print the measurement data. In addition to measuring the density of general solid and rubber and plastic particles, DH-300X can also measure the density of powder and liquid. It has complete functions and a wide range of applications.

The principle of solid-liquid dual-use electronic hydrometer

Using Archimedes' principle, based on: ASTM D792, ASTM D297, GB / T1033, GB / T2951, GB / T3850, GB / T533, HG4-1468, JIS K6268, ISO 2781, ISO 1183, GB / T 611, GB / T11540, GB / T12206, GB / T5518 and other standard specifications.

Main application industries

Mainly aimed at: rubber, plastic, wire and cable, tires, glass products, cemented carbide, chemical solutions, modern energy, petroleum fuels, fine chemicals, chemical reagents, chemical research laboratory, new materials research laboratory. It is suitable for density measurement in the fields of quality management, formulation modulation, cost control, and density research.

Technical parameters of solid-liquid dual-use electronic hydrometer

a) Density analysis: 0.001 g / cm3

b) Maximum weighing: 300g

c) Minimum weighing: 0.005g

d) Measuring range: 0.001-99.999g / cm3

Functional characteristics of solid-liquid dual-use electronic hydrometer

Solid features:

1. No manual calculation is required, and the test is more efficient, suitable for continuous multiple tests in the production site and laboratory

2. Plastic particles, films, floats, foams, vulcanized rubber, seals, calcium carbonate powder, etc. can be quickly measured

3. With direct reading measurement function of DIN volume wear, Akron wear, mass and volume change rate (expansion)

4. Fully automatic zero tracking, buzzer alarm, overload alarm function

5. With the actual water temperature compensation function, it can adapt to changes in the test environment

6. Use water as medium or other liquid medium

Liquid features:

1. The operation is in one step, which is convenient for multiple consecutive rapid tests

2. Any solution can be quickly measured

3. It can measure the sample density value under normal temperature to 100 ℃

4. Convenient sampling, the measured sample only needs 50CC

5. No cumbersome debugging and operation without Webster's balance method and pycnometer method

6. It can cooperate with constant temperature water tank operation and measure the specific gravity of the liquid at the required temperature

7. The measuring cup is easy to clean, not restricted by the small diameter of the pycnometer, and can be reused. At the same time, disposable measuring cups can also be used

8. Volatile liquids, corrosive liquids, viscous liquids, strong acids and alkaline liquids can be quickly measured (optional accessories)

Standard accessories

One main unit, one tweezers, one thermometer, one weight, one set of windproof and dustproof cover, one solid water tank, one solid measuring table, one particle measuring device, one set of accessories for measuring floats, and one liquid measurement placement plate , A liquid measurement bracket, a set of DE-20A standard liquid measurement components, a power transformer

Test procedure of solid-liquid dual-use electronic hydrometer

Solid measurement steps:

â‘  Put the product into the measuring platform, measure the weight in the air, and press ENTER to remember.

â‘¡Place the product in water to measure the weight in water, press ENTER to memorize, and display the density value.

Liquid measurement steps:

â‘ Place the beaker containing the sample on the measurement placement plate and deduct the weight of the hook.

â‘¡Put the standard weight into the liquid to be measured with a hook and hang it on the measuring frame, which is displayed as the density value.

After-sales service and commitment:

1. All products are original authentic products.

2. All products are guaranteed for one year free of charge, lifetime maintenance, all costs incurred during the warranty period shall be borne by us. (Except for natural disasters and man-made phenomena)

3. In the event of damage to the instrument during transportation, we shall bear all responsibilities and guarantee to replace the new product within 4 days.

4. How to use, we teach the buyer to use the technical staff until they are fully skilled.

5. For other detailed purchases, please refer to the contract terms agreed by both parties.

The above is the information of liquid hydrometer, solid hydrometer, solid-liquid dual-use electronic hydrometer, if you want to buy, please call Beijing Yitenuo Electronic Technology Co., Ltd.


Data Recharge Card

Guang Zhou SUNSEA Printing Technology CO.,LTD. , https://www.sansenprinting.com

Posted on