Mouse growth hormone releasing peptide ghrelin (GHRP-Ghrelin) ELISA kit, kit instructions

Enzyme-linked immunoassay of mouse growth hormone releasing peptide ghrelin (GHRP-Ghrelin)
Kit instruction manual
This kit is for research use only.
Detection range: 96T
60ng / L-1800ng / L
purpose of usage:
The kit is used to determine the content of growth hormone releasing peptide ghrelin (GHRP-Ghrelin) in mouse serum, plasma and related liquid samples.
Experimental principle
This kit uses double antigen sandwich method to determine the level of mouse growth hormone releasing peptide ghrelin (GHRP-Ghrelin) in the specimen. Microporous plates were coated with purified mouse growth hormone releasing peptide ghrelin (GHRP-Ghrelin) antigen to prepare solid-phase antigens, and growth hormone releasing peptide ghrelin (GHRP-Ghrelin) was added to the monoclonal antibody coated microwells in turn Combined with HRP-labeled growth hormone releasing peptide ghrelin (GHRP-Ghrelin) antigen to form an antigen-antibody-enzyme-labeled antigen complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the growth hormone releasing peptide ghrelin (GHRP-Ghrelin) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of mouse growth hormone releasing peptide ghrelin (GHRP-Ghrelin) in the sample was calculated by a standard curve.
Kit composition
1
30 times concentrated washing solution
20ml × 1 bottle
7
Stop solution
6ml × 1 bottle
2
Enzyme reagent
6ml × 1 bottle
8
Standard product (3600ng / L)
0.5ml × 1 bottle
3
Enzyme coated plate
12 holes × 8
9
Standard dilution
1.5ml × 1 bottle
4
Sample diluent
6ml × 1 bottle
10
Instructions
1 serving
5
Developer A liquid
6ml × 1 bottle
11
Sealing film
2 sheets
6
Developer B liquid
6ml × 1 / bottle
12
sealed bag
1
Specimen requirements
1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided
2. The samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
Steps
1. Dilution of standard products: This kit provides one original standard product. The user can perform dilution in small test tubes according to the following chart.
1800ng / L
Standard No. 5
150μl of original standard is added to 150μl standard dilution
900ng / L
Standard 4
150μl Standard No. 5 is added to 150μl standard dilution
450ng / L
Standard 3
150μl Standard No. 4 is added to 150μl Standard Diluent
225ng / L
Standard No. 2
150μl Standard No. 3 is added to 150μl Standard Diluent
112.5ng / L
Standard 1
150μl Standard No. 2 is added to 150μl Standard Diluent
2. Sample addition: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the operation is the same), standard wells, sample wells to be tested. Accurately add 50μl of the standard on the enzyme-coated plate, add 40μl of sample diluent to the sample well, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times) Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes.
4. Mixing solution: Dilute 30 times concentrated washing liquid with distilled water 30 times and reserve
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat this 5 times, pat dry.
6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
7. Incubation: The operation is the same as 3.
8. Washing: The operation is the same as 5.
9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 15 minutes.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.
Summary of operating procedures:
Calculation
Taking the concentration of the standard as the abscissa and the OD value as the ordinate, draw a standard curve on the coordinate paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply it by the dilution factor; or use the concentration of the standard Calculate the linear regression equation of the standard curve with the OD value, substitute the OD value of the sample into the equation, calculate the sample concentration, and multiply it by the dilution factor to obtain the actual concentration of the sample.
Precautions
1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5).
5. The sealing film is limited to one-time use to avoid cross-contamination.
6. Please keep the substrate away from light.
7. Strictly follow the instructions, and the test results must be determined by the microplate reader.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. The components of different batches of this reagent shall not be mixed.
10. If there is any difference with the English manual, the English manual shall prevail.
Storage conditions and validity period
1. Kit storage :; 2-8 ℃.
2. Validity: 6 months

The 6 seats golf carts our factory produce with gas and battery power,it can be with lights or without lights systems,without lights systems are mainly for golf course,have different colors for you choose.as forest green,white,bule.red.that style  incluce EZGO ,YAMAHA,CLUB CARtype, the extra options like rear flip seat,rain cover,,sun shade cover,music player,alloy rim,,ect are all available as your requirements, it widly used fortouring,park,etc, the motor we use is 4kw Ac Or 3kw Dc, battery is 150ah,6 cells 8 volt deep cycle storage battery that with the max range over 100kms for each charge, battery lifespan is up to 800 tims recharge cycles, we also accept all kinds of OEM services for our golf carts.